Ingenico Lane 3600
The Ingenico Lane/3600 is a customer-facing payment terminal that supports MSR (magnetic stripe), EMV (chip), and NFC (contactless) payments.
Connected to the cloud-based terminal service through a wired Ethernet connection, the device secures transactions using EMV technology and point-to-point encryption (P2PE), helping keep transactions secure and PCI compliant.
For detailed information on integrating the Lane/3600 with your application, refer to the CardPointe Integrated Terminal API.
Benefits and FeaturesBy integrating the Lane/3600 with your CardPointe Integrated Terminal solution, you can:
- Minimize your PCI compliance scope with point-to-point encryption. CardPointe Integrated Terminal encrypts sensitive card data and transmits it over a secure HTTPS connection.
- Accept all payment types, including MSR (magnetic swipe), EMV (chip), and NFC (contactless).
- Easily add devices without making changes to your existing integrations.
The following sections provide information for getting started with the Lane/3600.
What's in the Box?- Ingenico Lane/3600 terminal
- Ingenico Multipoint Interface Cable
- Ingenico power supply
- Plug the power supply connector into the jack on the Multipoint Interface Cable.
- Connect the Multipoint Interface Cable to the Multipoint Port on the underside of the terminal.
- Connect the other end of the Multipoint Interface Cable to an Ethernet port, such as a router, modem, or wall jack.
- Plug the power supply adapter into an available power outlet.
Once power is supplied to the terminal, the initialization process begins.
After the terminal successfully establishes an IP address, it attempts to connect to the terminal service.
- If the connection is successful, the device displays Connected.
- If the connection is unsuccessful, the device displays Disconnected. Contact CardPointe Support for assistance.
Once the device displays Connected, it is ready for use.
The device may remain powered on indefinitely or may be disconnected from power as needed.
Entering Text Using the Multi-Tap MethodSome setup and configuration tasks require entering characters using the keypad.
Each number key represents a set of letters that can be entered by pressing the key multiple times. The first key press enters the number, while additional key presses cycle through the associated letters.
For example:
- Press 2 once to enter the number 2
- Press 2 twice to enter lowercase a
- Press 2 three times to enter lowercase b
- Press 2 four times to enter lowercase c
- Press 2 five times to enter capital A
- Press 2 six times to enter capital B
- Press 2 seven times to enter capital C
After setup and configuration are complete, the terminal is ready for use. Additional advanced configuration changes can also be made, such as assigning a static IP address or changing the terminal password.
The following sections provide information on accessing the Admin Menu and performing additional configuration tasks.
Accessing and Navigating the Admin MenuThe Admin Menu provides access to:
- Settings
- Configuration
- Change Menu Password
- Restart Terminal
- Press F and enter the default password CCMerchant using the multi-tap method.
- Press O (green button) to confirm the password and access the Admin Menu.
- Press the down arrow to scroll down.
- Press the up arrow to scroll up.
- Press O (green button) to select.
- Press < (yellow button) to clear.
- Press X (red button) to cancel or return to the main menu.
- Access the Admin Menu.
- Press the down arrow to scroll down and select Change Menu Password.
- Enter the new password using the multi-tap method and press O (green button) when finished.
When complete, the device displays Menu password changed.
Exercise caution when changing the password and store it in a secure location.
This password cannot be reset remotely. If the password is forgotten or lost, access to the Admin Menu will no longer be available and the terminal will need to be replaced.
Setting a Static IP AddressSetting a static IP address is optional. In most cases, the device automatically receives an IP address when connected to the network.
To manually configure network settings:
- Access the Admin Menu.
- Press the down arrow and select Configuration.
- Press the down arrow and select IP Settings.
- Press the down arrow and select Configure IP.
- Press the down arrow and select Static IP.
- Enter the Static IP Address and press O (green button).
- Enter the Network Mask and press O (green button).
- Enter the Gateway Address and press O (green button).
- Enter DNS Address 1 and press O (green button).
- Enter DNS Address 2 and press O (green button).
The terminal displays Updating IP configuration and restarting terminal, then restarts using the new static network configuration.
To restore the default network configuration, repeat the steps above and select DHCP from the Select IP Protocol screen in step 5.
Configuring Device Beep SettingsThe Beep menu allows temporary adjustment of the device beep volume, pitch, and duration.
Note: This feature is intended for testing purposes only. To permanently change the device beep settings, note the preferred settings and contact CardPointe Support.
- Access the Admin Menu.
- Press O (green button) to select Settings.
- Press F2 to scroll down and select Beep.
- Enter a value for Frequency (Hz) using the keypad.
- Press the down arrow and enter values for Volume, Time On (ms), and Time Off (ms).
|
Parameter Name |
Default |
Range |
Description |
|
Frequency (Hz) |
100 |
20–20,000 |
Controls the pitch of the beep |
|
Volume |
100 |
1–100 |
Controls the volume as a percentage |
|
Time On (ms) |
250 |
10–5,000 |
Controls the length of each beep |
|
Time Off (ms) |
250 |
10–5,000 |
Controls the time between beeps |
Press O (green button) when finished.
The terminal displays Beep parameters have been updated and beeps several times to confirm the new settings.
Checking Your Device's Firmware Version- Access the Admin Menu.
- Press O (green button) to select Settings.
- Press O (green button) to select Version.
The current firmware version installed on the device is displayed on the screen.
Press X (red button) to return to the previous menu.
Troubleshooting
Restarting Your Terminal
You can restart the terminal using either of the following methods:
- To perform a soft reboot, access the Admin Menu and select Restart Terminal.
- To perform a hard reboot, press and hold the .,#* key and the < (yellow key) simultaneously until the device powers off.
Device Disconnected
If the device displays Disconnected, complete the following troubleshooting steps:
- Verify that you are using the provided multi-point mono connector (Ethernet) cable and power supply. The power supply should be connected to the splitter on the Ingenico multi-point mono connector cable.
- Verify that the Ethernet jack on the multi-point mono connector cable is securely connected to your router, modem, network switch, or Ethernet wall jack.
- Verify that the device was obtained from the CardPointe shop or your software provider.
- Consult your IT administrator to verify that the Ethernet port being used has internet access and that your internal network allows CardPointe Integrated Terminal connections. This helps ensure that a firewall is not blocking the connection.
Device Connected but Unable to Connect to Application
If the device displays Connected but is unable to connect to your application, complete the following steps:
- Confirm with your software provider that the device configuration is correctly set within your application.
- If the device configuration is correct and the issue persists, contact CardPointe Support for assistance.
Device Restarting Unexpectedly
The most common cause of a device restarting unexpectedly during the day is an incorrect time setting on the device.
Devices are configured to automatically restart at 4:00 AM local time. To update the device date and time settings, complete the following steps:
- Access the CardPointe Integrated Terminal menu.
- Scroll down to Date and Time.
- Press O (green button) to access the Date and Time settings.
- Enter the current date using the device number pad.
- Scroll down to the time field.
- Enter the current time in 24-hour format using the device number pad.
- Press O (green button) to save the settings.
PPS - 21 Invalid Merchant Error
If the terminal displays a PPS - 21 Invalid Merchant error, contact Merchant Support for assistance.
Contacting SupportCardPointe Support is available to assist with device setup, troubleshooting, and other support needs.
Before contacting support, have the following information available:
- Merchant ID
- Device hardware serial number (HSN)
- Any error messages displayed on the terminal
The HSN can be found at the top of the device display. Having this information available can help expedite the troubleshooting process. CardPointe Support